PRODUCTS - CONCRETE PIPE
Overview:
Geneva Pipe Company is one of the most respected
concrete product producers in the western United States.
With production from four facilities, Geneva
Pipe is able produce a large variety of concrete products. Our
strong
production flexibility coupled with quality engineering, allows
Geneva Pipe
to easily meet the normal everyday needs and requirements of specifiers.
With a full line of standard products, Geneva Pipe meets not only
your
routine needs but your specialty applications as well. We welcome
the
opportunity to accomplish the unique and the unusual specification.
The
Geneva Pipe product is designed and manufactured for strength,
durability,
extended service life, and ease of installation. The product line
covers
from 12 inches to 144 inches in diameter with most of the variations
and
variety required by products of this size and scope. Please contact
your
Geneva Pipe Representative for any technical assistance.
Circular Reinforced Concrete Pipe with Rubber Gasket:
ASTM C-76, ASTM 655, AASHTO M170, AASHTO M242
Nominal Pipe ID |
Bell OD |
Wall Thickness |
Joint Length |
Joint Weight |
Square Feet Area |
12 in |
20.00 in |
2.25 in |
8 Ft |
960 Lbs |
0.79 Sq Ft |
15 in |
23.88 in |
2.25 in |
8 Ft |
1080 Lbs |
1.23 Sq Ft |
18 in |
27.63 in |
2.50 in |
8 Ft |
1552 Lbs |
1.77 Sq Ft |
21 in |
27.63 in |
3.00 in |
8 Ft |
1920 Lbs |
2.41 Sq Ft |
24 in |
35.61 in |
3.00 in |
8 Ft |
2336 Lbs |
3.14 Sq Ft |
27 in |
38.00 in |
4.00 in |
8 Ft |
2842 Lbs |
3.98 Sq Ft |
30 in |
41.31 in |
4.13 in |
8 Ft |
4160 Lbs |
4.91 Sq Ft |
36 in |
51.19 in |
4.94 in |
8 Ft |
5040 Lbs |
7.07 Sq Ft |
42 in |
57.00 in |
5.12 in |
8/12 Ft |
810 Lbs/Lf |
9.62 Sq Ft |
48 in |
63.00 in |
5.71 in |
8/12 Ft |
989 Lbs/Lf |
12.57 Sq Ft |
54 in |
70.00 in |
5.50 in |
8/12 Ft |
1117 Lbs/Lf |
15.90 Sq Ft |
60 in |
76.55 in |
6.00 in |
8/12 Ft |
1532 Lbs/Lf |
19.64 Sq Ft |
66 in |
84.00 in |
7.25 in |
12 Ft |
21600 Lbs |
23.76 Sq Ft |
72 in |
88.00 in |
7.00 in |
8/12 Ft |
1842 Lbs/Lf |
28.27 Sq Ft |
84 in |
101.50 in |
8.75 in |
8/12 Ft |
2650 Lbs/Lf |
38.49 Sq Ft |
96 in |
115.50 in |
9.75 in |
8/12 Ft |
3375 Lbs/Lf |
50.27 Sq Ft |
Note: Please contact your Geneva Pipe Representative for any
pipe diameter not noted on the above graph. All pipes manufactured
by Geneva Pipe will adhere to ASTM or AASHTO requirements in regards
to reinforcement and concrete compressive strengths. Pipe dimensions
are subject to allowable tolerances and parameters of ASTM and
AASHTO Specifications.
Standard Specifications for Reinforced Concrete Pipe:
ASTM C76 – (most current)
• “Reinforced Concrete Culvert, Storm Drain, and Sewer
Pipe”
ASTM C76M – (most current)
• “Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe” (Metric)
ASTM C655 – (most current)
• “Reinforced Concrete D-Load Culvert, Storm Drain and Sewer
Pipe”
ASTM C655M – (most current)
• “Reinforced Concrete D-load Culvert, Storm Drain and Sewer
Pipe” (Metric)
AASHTO M170 (most current)
• “Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe”
AASHTO M170M (most current)
• “Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)”
AASHTO M242 (most current)
• “Reinforced Concrete D-load Culvert, Storm Drain, and Sewer
Pipe”
AASHTO M242M (most current)
• “Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer
Pipe (Metric)”

Applications:
• Storm Drains
• Sanitary Sewers
• Culverts
• Underground Stormwater Detention Systems
• Irrigation Systems
• Treatment plants
Design:
The project engineer should determine all concrete pipe strength
classifications (Classes I, II, III, IV, & V) and installation
criteria. In an effort to aid the design engineer in both the direct
and indirect design methods see the Education area available
on the home page of the Geneva Pipe website/catalog. For any additional information contact your Geneva Pipe Representative.
Click here to view additional pipe drawings.
Click here to review Type 3 fill height charts, standard trench/embankment installations and soil requirements.
Click here to review Pipe Lifting Devices.
For any additional
information contact your local Geneva Pipe Representative:
Email: info@genevapipe.com
Phone: 888-225-2416
Back to Top
Circular Non-Reinforced Concrete Pipe with Rubber Gaskets
ASTM C-14, AASHTO M86
Nominal Pipe ID |
Bell OD |
Wall Thickness |
Joint Length |
Joint Weight |
Square Feet Area |
12 in |
20.00 in |
2.25 in |
8 Ft |
960 Lbs |
0.79 Sq Ft |
15 in |
23.88 in |
2.25 in |
8 Ft |
1080 Lbs |
1.23 Sq Ft |
18 in |
27.63 in |
2.50 in |
8 Ft |
1552 Lbs |
1.77 Sq Ft |
21 in |
27.63 in |
3.00 in |
8 Ft |
1920 Lbs |
2.41 Sq Ft |
24 in |
35.61 in |
3.00 in |
8 Ft |
2336 Lbs |
3.14 Sq Ft |
27 in |
38.00 in |
4.00 in |
8 Ft |
2842 Lbs |
3.98 Sq Ft |
30 in |
41.31 in |
4.13 in |
8 Ft |
4160 Lbs |
4.91 Sq Ft |
36 in |
51.19 in |
4.94 in |
8 Ft |
5040 Lbs |
7.07 Sq Ft |
Note: All non-reinforced concrete pipe manufactured
by Geneva Pipe will adhere to the requirements of ASTM and AASHTO
specifications. All dimensions are subject to allowable tolerances
and parameters of those specifications.

Standard Specifications for Non-Reinforced Concrete
Pipe:
ASTM C-14 (most current)
• “Concrete Culvert, Storm Drain, and Sewer Pipe”
ASTM C-14M (most current)
• “Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)”
AASHTO M86 (most current)
• “Concrete Culvert, Storm Drain, and Sewer Pipe”
AASHTO M86M (most current)
• “ Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)”
Applications:
• Storm Drains
• Culverts
• Irrigation Systems
Design:
The project engineer should determine all concrete pipe strength
classifications (Classes 1, 2, & 3) and installation criteria.
In an effort to aid the design engineer in both the direct and
indirect design methods see the Software / Education area available
on the home page of the Geneva Pipe website/catalog or contact your Geneva Pipe Representative.
Click here to view additional pipe drawings.
Click here to review Pipe Lifting Devices.
For any additional
information contact your local Geneva Pipe Representative:
Email: info@genevapipe.com
Phone: 888-225-2416
Back to Top
Elliptical
Concrete Pipe with Joint Sealant:
ASTM C-507, AASHTO M207
Nominal Pipe Size |
Circular Equivalent |
Joint Weight |
Wall Thickness |
Joint Length |
Square Feet Area |
14" x 23" |
18 in |
1665 Lbs |
3.00 in |
8.0 Ft |
1.8 Sq Ft |
19" x 30" |
24 in |
2560 Lbs |
3.50 in |
8.0 Ft |
3.3 Sq Ft |
24" x 38" |
30 in |
3670 Lbs |
3.75 in |
8.0 Ft |
5.1 Sq Ft |
29" x 45" |
36 in |
5000 Lbs |
4.50 in |
7.5 Ft |
7.4 Sq Ft |
34" x 53" |
42 in |
6520 Lbs |
5.00 in |
7.5 Ft |
10. 2 Sq Ft |
38" x 60" |
48 in |
8335 Lbs |
5. 75 in |
8.00 Ft |
12.9 Sq Ft |
Note: For elliptical pipe sizes larger than noted on graph please
contact your Geneva Pipe Representative. Area of reinforcement,
number of cages, and concrete compressive strengths shall be in
conformance with appropriate ASTM / AASHTO specifications for Class
HE-A, HE-I, HE-II, HE-III, or HE-IV as required. All dimensions
are subject to allowable tolerances and parameters of those specifications.

Standard Specifications for Elliptical Concrete Pipe:
ASTM C-507 (most current)
• “Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer
Pipe”
ASTM C-507M (most current)
• “Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer
Pipe (Metric)”
AASHTO M207 (most current)
• “Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer
Pipe”
AASHTO M207M (most current)
• “Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer
Pipe (Metric)”
Applications:
• Storm Drains
• Underground Detention Systems
• Culverts
• Sanitary Sewers
Design:
The project engineer should determine all concrete pipe strength
classifications (Classes HE-I, HE-II, HE-III, & HE-IV) and
installation criteria. In an effort to aid the design engineer
in both the direct and indirect design methods see the Software
/ Education area available on the home page of the Geneva Pipe
website/catalog. For any additional information contact your Geneva Pipe Representative.
Click here to view additional pipe drawings.
Click here to review Pipe Lifting Devices.
Jacking / Microtunneling Pipe

Uses:
• Storm Drains
• Sanitary Sewers
• Culverts
Specifications:
All specifications are project specific. Please contact Geneva Pipe to assure that all pipes are
manufactured to meet the appropriate project specifications.
This pipe can be designed for both sanitary and storm applications. Please review specific diameters
and the Geneva Pipe Jacking Guidelines located on our Pipe Drawing Page. For any specific diameter
not shown on the Pipe Drawing Page, please call your Geneva Pipe Representative.
Click here to view Jacked Pipe drawings and guidelines.
Click here to review Pipe Lifting Devices.
For any additional information contact your local Geneva
Pipe Representative:
Email: info@genevapipe.com
Phone: 888-225-2416
Back to Top
|